ASCII I/O Module Tutorial

Chapter 4

4Ć41

1.

Increase the number of initialization words to four by setting
appropriate bits. Set IW1=0003. Use procedure in section titled
“String Length Less Than Module’s String Length”, P. 3-10.

2.

Select the slash symbol (/) as the fill character to be removed using
procedure in section titled “Setting Bits In Initialization Words”, P.
3-30. The ASCII / is 2F in hex. Set IW4 = 2F00.

Display The initialization word file is displayed in hex and binary,
respectively, as follows:

RADIX = %H START = WO007:0000

WORD #

00000

0

0000

1

0000

2

0003

3

0015

4

0D00

5

2F00

START = WO007:0000

WORD #

00000

2

000000000000010

3

0000000000010101

4

0000110100001000

5

0010111100000000

NOTE: Binary words 0 and 1 were omitted for brevity.

3.

Enter: //AS//23//AS//4[ENTER]

Refer to procedures in section titled “Reading Data From Your ASCII
Device” (P. 1-28).

Procedure P1

Connect the 1770ĆCB cable, and set your industrial

terminal to alphanumeric mode (check parameters)

Initialize the module by changing PLCĆ3 operation mode

3[ENTER]2[ENTER]

Procedure P2

Enter your data

Procedure P3

Connect the 1775ĆCAT cable, and set your industrial

terminal to PLCĆ3 mode

Procedure P4

Observe how the data string is stored in data table file O6:0

Results The module transferred the data characters, extracted the fill
character, added its own fill character, and right justified the data.