Choosing Module Features

Chapter 3

3Ć16

Table 2.H

Margin Justification

When

Justified

Each New Line Is Displayed

with the Same

and Data Is Stored in the Data

Table by Placing

Left

Left margin

Example: Text is left justified.

The first character in the upper byte of the

lowest word address. Blanks or zeros fill the

higher word addresses.

Example: PLCĆ2 Family

ABCD

EF00

0000

Example: PLCĆ3 Family

A B C D E F 0 0 0 0 0 0

Right

Right margin

Example: Dollar values are right

justified

The last character in the lower byte of the

highest word address. Blanks or zeros fill the

lower word addresses.

Example: PLCĆ2 Family

0000

00AB

CDEF

Example: PLCĆ3 Family

0 0 0 0 0 0 A B C D E F

Table 2.I

Margin Justification/Mode of Operation

When

Module

Mode of

Operation Is

Your Justification Is

Data Mode

Either left or right (you select)

Report

Generation

Mode

ASCII data is left justified. BCD values, contained in the string of ASCII data, are right

justified.

Record your selection based on your choice of module operation. If you
choose data mode, choose either left justification IW3(03) =1 or right
justification IW3(03)=0. Record your selection by writing a 1 or 0 in
IW3(03) using the form (found at the end of this chapter) or the box pn
the next page.