ASCII I/O Module Tutorial

Chapter 4

4Ć45

Results The file displays the 15 data characters, which include ASCII
characters and BCD values segregated by delimiters.

RADIX = %H START = WO006:0000

WORD #

00000

0

0000

1

0000

2

4142

3

4344

4

002F

5

1234

6

2F35

7

3641

00010

4243

0000

0000

0000

0000

0000

0000

0000

RADIX = %A START = WO006:0000

WORD #

00000

0

00H00H

1

00H00H

2

A B

3

C D

4

00H /

5

12H 4

6

/ 5

7

6 A

00010

B C

00H00H 00H00H

00H00

00H00H 00H00H 00H00H 00H00H

Notice the following:

The BCD delimiter is stored as a character in the string.
The number of characters transferred is 15.
The data is stored in seven words.
The ASCII display did not correctly present BCD digits (see hex

display). The industrial terminal cannot correctly display BCD values
in an ASCII display.

3.

For comparison of data storage, enter the following. The BCD
delimiter segregates five digits instead of four.

Enter ABCD/12345/6ABC[ENTER]

Results The file displays 15 data characters, which include ASCII
characters and BCD values segregated by delimiters.

RADIX = %H START = WO006:0000

WORD #

00000

0

0000

1

0000

2

4142

3

4344

4

002F

5

0001

6

2345

7

2F36

00010

4142

4300

0000

0000

0000

0000

0000

0000

RADIX = %A START = WO006:0000

WORD #

00000

0

00H00H

1

00H00H

2

A B

3

C D

4

00H /

5

00H01H

6

# E

7

/ 6

00010

A B C

00H

00H00H

00H00

00H00H 00H00H 00H00H 00H00H