Getting Started with Your ASCII Module

Chapter 2

2Ć34

1.

Connect the 1770-CB cable to channel B.

2.

Select alphanumeric mode.

Press [SHIFT][MODE]2

3.

Check operating parameters:

Communication rate is 300 baud.
Hardware handshaking is ON.
DUPLEX is FULL.
B and C are any setting.
E, and G thru M are OFF.
Press [ENTER] to load parameters.

The module’s CHANNEL ACTIVE LED turns on.

4.

Change the operation of your PC-3 controller to run monitor from
the PLC-3 front panel.

Press [SHIFT][LIST]2[ENTER]

Procedures P6
Enable the Transfer of New Data

1.

Set bit I001/02 to enable program logic (the write block transfer
handshaking) using the PLC-3 front panel.

Press [CLEAR][SHIFT]I0[SHIFT][BIT]1[BIT]2
[DISPLAY]

The front panel displays the bit address with an asterisk showing its
status, 1 or 0.

I000:0001/02*0

2.

Set the bit using the PLC-3 front panel.

Press 1 [ENTER]

Results The industrial terminal displays