Choosing Module Features

Chapter 3

3Ć26

Record your choice by writing a 0 (single transfer) or 1 (multiple transfer)
in IW2(17). Use the form (found at the end of this chapter) or the boxes
below.

IW2

Single

or Multiple

17

Transfers

When using an unbuffered data terminal, select a time for the ASCII
module to delay outputting data while the mechanical carriage return is
operating. Your selections are:

Delay Time (ms)

Code

0

00

50

01

100

10

200

11

Record your selection by writing the code in IW3(07,06) using the form
(found at the end of this chapter) or the boxes below.

IW3

Delay for

Carriage Return

07 06

Set the remaining bits in initialization word one according to the
specifications of your ASCII device.

Selecting Delay for Carriage

Return, IW3(06Ć07)

Setting Remaining Bits in

IW1(10Ć17)