ASCII I/O Module Tutorial

Chapter 4

4Ć18

Table 3.K

Display of Converted Data

Line

Conversion

Display

Notes

1

2

3

4

5

2 ASCII/word

1 ASCII/word

4 Hex/word

4 BCD/word

3 BCD/word

1 2 3 4 A B C D + M 0

2 4 B D + 0

3132 3334 4142 4344 20AB CDEF

3132 3334 4142 4344 20AB CDEF

132 334 142 344 0AB DEF

1

1 2

3

1 Ć 2 ASCII/word conversion examines the 7 bit code in each byte: AB=10101011=+;

CD=11001101=M; EF=11101111=o (Note that lower case letters are displayed as upper case

letters.)

2 Ć Bits 10Ć17 are not used in 1 ASCII/word conversion

3 Ć Bits 14Ć17 are not used in 3 BCD/word conversion

Verify the conversions (Table 3.K) as follows:

1. Load the file of the file-to-file move instruction (rung 15) starting at

position 001 exactly as shown in Table 3.J. Use procedure P3 and P5
from “Writing Data to Your ASCII Device”, P. 1-14.

Procedure P3 Set your industrial terminal to PLCĆ2 mode

Procedure P5 Load data into the fileĆtoĆfile move instruction

2. Set initialization word one to data mode, and select three

initialization words. Set IW1=0002. Use the procedure in section
titled “Setting Bits in Initialization Words”, P. 3-4.

3. Change your data conversion to 2 ASCII characters per word and set

the string length to 12, (IW2=0012).

4. Remove the BCD delimiter from initialization word four. Set

IW4=0000.

5. Change operation of your industrial terminal to alphanumeric mode.

Transfer data to the industrial terminal by changing the processor
mode select switch to the RUN/PROG position.

Results The industrial terminal displays

1234ABCD+M0(table 4.K, line1)

6. Verify the remaining conversions in lines 2, 3, 4 and 5 (Table 3.K) by

setting IW2(16-14) as follows: