ASCII Module

PLC-2 Family Processors

Appendix A

AĆ29

T0004

RUNG NUMBER RM18

TON

TIMER ON

1.0 SECOND

TP =

TA =

T0004

60

9

T0004

17

TE

T0004

15

TD

15

Free-running timer for message format

I0001

RUNG NUMBER RM19

04

demonstration

MOV
MOV FROM A TO R
A : WTACC:0004

9

R : WD006:0007

9

MOV
MOV FROM A TO R
A : WTACC:0004

9

R : WD006:0007

0000000000001001

Moves free-running timer

accumulated value into

message file between

delimiters

I0001

04

MOV
MOV FROM A TO R
A : WTACC:0004

9

R : WO009:0007

0000000000001001

For comparison only

I0001

04

MVF

FILES FROM A TO R

A : FO006:0002

R : FO002:0002
COUNTER : C0005
POS/LEN = 62/ 62
MODE = ALL/SCAN

C0005

12

EN

C0005

15

DN

C0005

13

ER

Moves message file into BTW file

for transfer to module

EOP