Getting Started with Your ASCII Module

Chapter 2

2Ć29

4.

Set operating parameters:

Communication rate to 300 baud. Press A (as needed) until the

communication rate, as displayed on the screen, reaches 300 baud.

Hardware handshaking to ON. Press D
DUPLEX to FULL. Press F
B and C to any setting.
E, and G thru M to OFF.
Press [ENTER] to load parameters.

The prompt, ENTERING ALPHANUMERIC TERMINAL MODE, tells
you the terminal is ready for your input.

Procedure P2
Enter Your Data

1.

Check that the PLC-3 controller is operating in run monitor. Use the
PLC-3 front panel.

Press [SHIFT][LIST] 2 [ENTER]

2.

Enter data, such as your first name, followed by a couple of numbers.
Enter 11 characters counting the space between your name and
numbers. Select the characters from commonly used data characters
(Table 1.D).

Table 1.D

Commonly Used Data Characters

ASCII

Hex

ASCII

Hex

ASCII

Hex

space

20

A

41

N

4E

0

30

B

42

O

4F

1

31

C

43

P

50

2

32

D

44

Q

51

3

33

E

45

R

52

4

34

F

46

S

53

5

35

G

47

T

54

6

36

H

48

U

55

7

37

I

49

V

56