A write example write (only) program, Ać45, Ascii module plc-2 family processors appendix a – Rockwell Automation 1771-DA,D17716.5.13 U MNL 1771-DA ASCII I/O MODULE User Manual

Page 213: Example write (only) program

Advertising
background image

ASCII Module

PLC-2 Family Processors

Appendix A

AĆ45

A write (only) program for transferring data from your processor’s data
table to your ASCII device is presented with rung descriptions in
Figure A.19.

Figure A.19

Example Write (Only) Program

I0001

00

WO005:0000

00

MOV
MOVE FROM A TO R
A : WO0001:0000
0000000000000000
R : WO0002:0000
0000000000000000

RUNG NUMBER RM0

Load zeros into command word 1 with

selector switch or on first scan

RUNG NUMBER RM1

WO003:0000

07

WO002:0000

07

Power-up/reset power-up initialization bit

WO003:0000

07

S0003

01

WO005:0000

01

L

RUNG NUMBER RM2

WO005:0000

RUNG NUMBER RM3

TON

TIMER ON

1.0 SECOND

TP =

TA =

T0001

2

0

T0001

17

TE

T0001

15

TD

01

Energize at power-up to load initialization words. Also energized on
on 1st scan after processor selection of run monitor mode

Energize timer on power-up

WO005:0000

01

T0001

15

RUNG NUMBER RM4

U

De-energize timer after transferring initialization words

I0001

00

WO005:0000

WO002:0000

17

RUNG NUMBER RM5

Command word 1 initialization bit. Module expects

up to 4 initialization words

01