Function of Control/Status Bits

Chapter 6

6Ć19

Command Word One

Bit

Function

Status

17

Initialization

0 = Reset

1 = Up to four initialization words will follow

command words CW1 CW2

16

Write Data Available

Toggled status, CW(16)

SW(16), tells

module that transfer contains new data

15

Read Data Acknowledge

Toggled status, CW(15) = SW(15), tells

module that processor received previous

transfer

14

Incomplete String

0 = Reset

1 = Used for installation debugging, not for

normal operation

13

Port Disable

0 = Reset

1 = Disables communication thru the interface

port

12

Self Diagnostics

0 = Reset

1 = Enables self diagnostics. You must reĆ

initialize the module

11, 10

Not used

Set them to zero

07

Resets PowerĆup and

Handshaking

0 = Reset

1 = Resets SW1 (07) Initialization bit,

SW1(15) Read data available bit, and

SW1(16) Write data acknowledge bit

06, 05, 04 Not used

Set them to zero

03

Resets Input Buffer

Full Bit

0 = Reset

1 = Resets SW1(03) buffer full

02

Not used

Set it to zero

01

Reserved for future

use

Reset this bit to zero

00

Reserved for future

use

Reset this bit to zero