Returning data to the plc – Rockwell Automation 2706 DL40 HARDWARE USER MANUAL User Manual

Page 101

Advertising
background image

Chapter 10
Using Remote I/O

10 – 9

Block Transfer Enabled

Data in Discrete I/O Image Tables ignored.

Amount of data sent/returned independent of rack size.

Triggering the Same Message Twice in a Row

To avoid needless retriggering of a message via the I/O scan, the DL40 looks
for changes to the Message Number in the Output Image or Block Transfer
Write to trigger messages. To trigger the same message twice in a row, you
must:

trigger the message the first

time.

trigger a message with a Message Number of 0.

trigger the original message a second time.

Note: In Message/Variable/Slave Run Mode, changing the slave address will
also retrigger the same message.

The DL40 returns two types of data to a PLC:

ASCII Input Data

Clock/Date Data

ASCII Input Data

The DL40 returns ASCII Input Data during the PLCs I/O scan as part of the
Input Image Table or Block Transfer Read Data Table. This happens
automatically unless you request that Clock/Date Data be returned. You can
input ASCII Input Data only via the keyboard port. This data is cleared after
one scan or read.

Clock/Date Data

There are two ways to request the DL40 return Clock/Date Data:

Set

Always

Send Clock Data

to

yes

.

Note:

Always Send Clock Data

is a parameter of the

Triggering Port

Setup

for Remote I/O.

Trigger Special Message 912 (time) or 913 (date).

Note: The PLC must internally keep track of which Special Message was
triggered to determine if time or date data is being returned.

Returning Data to the PLC