Inputting ascii input data via the keyboard port – Rockwell Automation 2706 DL40 HARDWARE USER MANUAL User Manual
Page 83

Chapter 8
Serial Communications
8 – 6
[CTRL][A]
ASCII Data
Backslash
( \ )
DL40
Address
[
↵
]
where:
Data
Acceptable Values
ASCII Data
1 to 20 ASCII characters. Data is for the latest message sent to
the specified DL40.
DL40 Address
1 to 3 digits (0 to 127)
127 = all DL40s on RS-485 link
Note: The DL40 address is not required for
[CTRL][W]
data (ASCII Variable
Data) entered via the keyboard. If no DL40 address is sent, the backslash ( \ )
is optional. If no address is sent when using the RS-485 link, the ASCII data
will be ignored.
When ASCII Input Data is required in a message, the message will have
underscored spaces. A flashing cursor will mark the position of the ASCII
character.
ASCII Input Data to fill
[CTRL][X]
callouts is input via the keyboard using
the following format:
ASCII (keyboard characters) data [CR]
ASCII Data
[
↵
]
where:
Data
Acceptable Values
ASCII Data
1 to 20 ASCII characters. Data is for the latest message sent to
the specified DL40.
Note: ASCII Input Data can only be returned via the RS-485 Port if the
message was triggered via the RS-485 Port or via the Remote I/O Port if the
message was triggered via the Remote I/O Port.
Inputting ASCII Input Data via
the Keyboard Port