Chapter 12
DIP Switch Settings

12 – 12

Setting Switch Bank #1

Note: A DIP switch is ON when in the “up” position.

Table 12.J
Setting Switch Bank #1 on Dataliner DL40 Displays (Parallel Port Units)

Switch Settings

Switch

Description

OFF

ON

1

Not Used

2

Debug

Disabled

Enabled

3

Fast Reset

Disabled

Enabled

4

Not Used

5

Not Used

6

Keyboard

IBM–AT

IBM–XT

7

Not Used

8

Not Used

9

Select Enable

Disabled

Enabled

10

Not Used

Debug (Switch #2)

If the Debug DIP switch is set to ON, then the current state of all of the
parallel port inputs will be displayed on the DL40 at power up. If the Debug
DIP switch is set to OFF, then the DL40 will enter the run mode at power up.

Fast Reset Sequence (Switch #3)

If the Fast Reset DIP switch is set to ON, the DL40 will display only the
Firmware Version, Screen Test, and the Selected Run Mode. All other
prompts will be skipped (but the tests will still be run). If any of the tests fail,
then that error message will still appear. If the Fast Reset DIP switch is set to
OFF, the DL40 will display the Firmware Version, Memory Verification,
External Module Verification, Screen Test, RS-232 Port Settings, RS-485
Port Settings, and the Selected Run Mode.

Keyboard Type (Switch #6)

If the Keyboard Type DIP switch is set to ON, then an IBM-XT or
compatible is the only type of keyboard that can be used. If the DIP switch is
set to OFF then the IBM-AT or compatible is the only type of keyboard that
can be used.

Select Enable (Switch #9)

If the Select Enable DIP switch is set to ON, then the SELECT button on the
faceplate of the DL40 is enabled. If the Select Enable DIP switch is set to
OFF, then the SELECT button on the faceplate of the DL40 is disabled.