Rockwell Automation 2706 DL40 HARDWARE USER MANUAL User Manual

Page 44

Advertising
background image

Chapter 5
Special Messages

5 – 5

This message will be put at the end of the queue and will only be run after all
messages before it have been run.

This message terminates and retains new settings if either:

no new setting is received for 20 seconds

Special Message 915 (Stop Special Message/Resume Run Mode) is
triggered.

Message terminates and loses all new settings if either:

Special Message 901, 903, or 904 is triggered

Run Mode is Exited

911 (or 11) Set Clock with Variable Data

Sets clock with data sent as a variable. Functions only in Message/Variable
and Message/Variable/Slave Run Modes since Message List and Bit Trigger
Run Modes do not support variables.

Table 5.B
Setting clock with data sent as a variable

Variable Number

Contains

Acceptable Values

1

Minutes

0–59

2

Hours

1–12 or 0–23

3

Date

1–31

4

Month

1–12

5

Year

0–99

6

Mode

0=AM
1=PM
2=24 hr

Note on using Discrete I/O: Since the number of variables that can be sent
depends on the rack size, small rack sizes cannot set all clock parameters.

This message will be put at the end of the queue and will only be run after all
messages before it have been run.

This message terminates and retains new settings if either:

no new setting is received for 20 seconds

Special Message 915 (Stop Special Message/Resume Run Mode) is
triggered.

Message terminates and loses all new settings if either:

Special Message 901, 903, or 904 is triggered

Run Mode is Exited

Advertising