Appendix A
Error & Status Messages
A – 5
Message
Meaning
Type
VARIABLE SPACE FULL
On–Board Editor
Error
Each message in the DL40 can contain a limited
number of formatted (Ctrl V) or ASCll BCD (Ctrl W)
variables. A total of 40 variable units are allowed.
Each (Ctrl V) variable requires 4 units. Each (Ctrl W)
variable uses 2 units if CTRL–W MEANS ASCII Each
(Ctrl W variable uses 1 unit if CTRL–W MEANS BCD.
VERSION x.xx y LINE
Configuration/Status
During Power–Up
Message
This is the first thing displayed by the DL40 when
powered or reset. x.xx is the release number of the
installed DL40 firmware. y is the number of display
lines on the DL40, either 2 or 4.