Keyboard port, Parallel input port 5 to 24 volts dc, Parallel input port communications – Rockwell Automation 2706 DL40 HARDWARE USER MANUAL User Manual

Page 153: Environmental specifications, Weights

Advertising
background image

Chapter 13
Specifications

13 – 2

Keyboard Port

Type

IBM-XT, -AT

Connector

8 pin DIN

Parallel Input Port 5 to 24 volts DC

Note: 120 volts AC

±

10% (47–63 Hz) can be used but only with optional input

converters.

Voltage Range

High True Logic

Low True Logic

0 – 0.8 VDC

0 (OFF)

1 (ON)

0.8 – 3.5 VDC

Indeterminate

Indeterminate

3.5 – 24 VDC

1 (ON)

0 (OFF)

Parallel Input Port Communications

Data Lines

16

Strobe Lines

4

Output

+ 12 Volts DC out, 300mA maximum

Input

8mA per data line at 12 Volts DC

Environmental Specifications

Operating Temperature

0

°

to +60

°

C (+32

°

to + 140

°

F)

Storage Temperature

–40

°

to +85

°

C (–40

°

to +185

°

F)

Humidity

5% to 95% (no condensation)

NEMA Rating

NEMA Type 1,12,13 and 4X (indoor) (when
mounted in a suitable enclosure)

Device Rating

UL Listed
CSA Certified

Weights

2 Line Units

7.4 lbs. (3.4 kg.)

4 Line Units

9.2 lbs. (4.2 kg.)

Advertising