Rockwell Automation 2706 DL40 HARDWARE USER MANUAL User Manual

Page 72

Advertising
background image

Chapter 7
Messages

7 – 9

Important: To send any message to a slave,

Port Use

for the RS-485 port

must be set to

DL Slave

. Refer to page 6 – 12 for information

on Ports.

If the

AutoReplace

attribute is active, the message will be sent to the slave

each time it repeats. If the message has embedded variables, it will be sent to
the slave each time new variable values are received during the message wait
time. Possible values for this field include:

Entry:

Which means:

0

Don’t send to slave

1 through 126

Send to the single identified slave address

127

Send to all slaves

Wait Time

This setting can mean either of two things to the message display.

If you have activated

Scroll message

, the value here represents the

scrolling rate in tenths of a second. For example, a value of 8 here will result
in display of the next new character in a message every 0.8 seconds.

If

Scroll message

is not active, then the value here represents the number

of seconds a message will appear on the message display. For example, a
value of 5 here will assure that the message will appear on screen for 5
seconds whenever it runs.

Acceptable values for this field can range from 0 through 31.

AutoClear

Activating this attribute instructs the DL40 to clear the message from the
display after the

Wait Time for message

has expired even if no other

messages have been triggered.

This value applies only to the lines used by a single message. For example, if
this message uses only lines 2 and 3, then only lines 2 and 3 will be cleared.
Lines 1 and 4 will remain unchanged.

Important: AutoClear will de-energize the alarm relay only if the message

which was cleared had energized the relay. A DL50 slave
message display must always be sent a message that
de-energizes the relay.

Type

[Y][

]

to activate or

[N][

]

to deactivate.