General precautions, Commissioning support, General precautions commissioning support – Rockwell Automation 7000 PowerFlex Medium Voltage AC Drive (B Frame) Commissioning - ForGe Control User Manual

Page 10

Advertising
background image

10

Rockwell Automation Publication 7000-IN012B-EN-P - June 2014

Chapter 1

Important User Information

Rockwell Automation provides the site- and installation-specific electrical and
design information for each drive during the order process cycle. If they re not
available on site with the drive, contact Rockwell Automation.

If you have multiple drive types or power ranges, ensure you have the correct
documentation for each specific PowerFlex 7000 product:

“A” Frame for lower power air-cooled configurations (up to approximately
1250 hp/933 kW)

“B” Frame for higher-power, air-cooled configurations (heat sink or heat
pipe models)

“C” Frame for all liquid-cooled configurations

General Precautions

Commissioning Support

After installation, Rockwell Automation Medium Voltage Support is responsible
for commissioning support and activities in the PowerFlex 7000 product line.

Phone: 519-740-4790

Option 1 for technical and option 4 for commissioning questions

[email protected] or
[email protected]

Rockwell Automation support includes, but is not limited to:

quoting and managing product on-site start-ups

quoting and managing field modification projects

quoting and managing customer in-house and on-site product training

ATTENTION: This drive contains ESD (Electrostatic Discharge) sensitive parts
and assemblies. Static control precautions are required when installing, testing,
servicing or repairing this assembly. Component damage may result if ESD
control procedures are not followed. If you are not familiar with static control
procedures, reference Allen-Bradley publication 8000-4.5.2, “Guarding Against
Electrostatic Damage” or any other applicable ESD protection handbook.

ATTENTION: An incorrectly applied or installed drive can result in component
damage or a reduction in product life. Wiring or application errors, such as,
undersizing the motor, incorrect or inadequate AC supply, or excessive ambient
temperatures may result in malfunction of the system.

ATTENTION: Only personnel familiar with the PowerFlex 7000 Adjustable
Speed Drive (ASD) and associated machinery should plan or implement the
installation, start-up and subsequent maintenance of the system. Failure to
comply may result in personal injury and/or equipment damage.

Advertising