Table 14 - Typical Application Load Torque Profiles

(1)

Application

Load Torque
Profile

Load Torque as Percent of Full-Load Drive Torque

Required Drive
Service Duty Rating

Encoder Required for
Extra Starting
Torque?

Break-away

Accelerating

Peak Running

AGITATORS

Liquid CT

100

100

100

Heavy

Yes

Slurry

CT

150

100

100

Heavy

Yes

BLOWERS (centrifugal)

Damper closed

VT

30

50

40

Normal

No

Damper opened

VT

40

110

100

Normal

No

CHIPPER (WOOD)—
starting empty

CT

50

40

200

Contact factory

No

COMPRESSORS

Axial-vane, loaded

VT

40

100

100

Normal

No

Reciprocating, starting
unloaded

CT

100

100

100

Contact factory

Yes

CONVEYORS

Armored face

CT

175

150

200

Contact factory

Yes

Belt type, loaded

CT

150

130

100

Heavy

Yes

Drag type

CT

175

150

100

Contact factory

Yes

Screw type, loaded

CT

200

100

100

Contact factory

Yes

DRAG LINE

CT

100

200

200

Contact factory

Yes

EXTRUDERS
(rubber or plastic)

CT

150

150

100

Contact factory

Yes

FANS (centrifugal, ambient)

Damper closed

VT

25

60

50

Normal

No

Damper open

VT

25

110

100

Normal

No

FANS (centrifugal, hot gases)

Damper closed

VT

25

60

100

Normal

No

Damper open

VT

25

200

175

Contact factory

No

FANS (propeller, axial
flow)

VT

40

110

100

Normal

No

GRINDING MILL
(Ball/Sag Mill)

CT

175

180

100

Contact factory

Yes

HOISTS

CT

100

200

200

Contact factory

Yes

KILNS (rotary, loaded)

CT

250

125

125

Contact factory

Yes

MIXERS

Chemical

CT

175

75

100

Contact factory

Yes

Liquid

CT

100

100

100

Heavy

Yes

Slurry

CT

150

125

100

Heavy

Yes

Solids

CT

175

125

175

Contact factory

Yes

PULPER

VT

40

100

150

Contact factory

No