Configuring Axis Use
5. Place the pointer in the Torque Limit data input box, and click the left
mouse button. This brings focus to the Torque Limit field. GML
Commander automatically generates a new Velocity Limit for the
lowered Torque Limit value.
6. Repeat steps 3 through 5 until you reach the desired Velocity Limit
(or absolute limit) for your motor.
For Custom motors:
1. At the beginning of your diagram, create a module that contains a
Control Settings block, with Adjust Type selected, for each of the
following data parameters:
D91
Motor Inertia 1394
D92
Motor Rated Speed 1394
D93
Motor Rated Current 1394
D94
Motor ID Start RPM 1394
D95
Motor ID End RPM 1394
D96
Motor ID Slope 1394
D97
Motor Resolver Offset 1394
D104
Motor RPM 100% Rated 1394
D105
Motor RPM 300% Rated 1394
D111
Motor Poles 1394
D112
Resolver Poles 1394
Refer to your motor’s documentation for parameter values.
2. Follow steps, 1 through 6, for listed motors, above.