Rockwell Automation GMLC Reference Manual User Manual
Page 222

Publication GMLC-5.2 - November 1999
Reset Fault
185
Selecting Reset 1394 clears all of the following 1394 system faults:
•
Axis_bus_loss_fault_1394
•
Axis_Drive_over_temp_fault_1394
•
Axis_it_fault_1394
•
Axis_module_hard_fault_1394
•
Axis_Motor_over_temp_fault_1394
•
Axis_power_fault_1394
•
Drive_hard_fault_1394
•
DSP_feedback_fault_1394
•
System_bus_over_voltage_flt_1394
•
System_bus_undr_voltage_flt_1394
•
System_control_power_fault_1394
•
System_ground_fault_1394
•
System_over_temp_fault_1394
•
System_phase_loss_fault_1394
•
System_serial_ring_fault_1394
•
System_smrt_pwr_i_limit_fault_1394
•
System_smrt_pwr_pre_charge_fault_1394
•
System_smrt_pwr_shunt_timeout_fault_1394
Selecting Reset 1394 clears the latched fault only if the fault itself is not
active. In addition, this selection causes the controller to try to re-initialize
the drive module(s) interface with their configured parameters.
Selecting Reset 1394 does not clear axis faults that are cleared by the Axis
Fault or All Faults selections.