Data Parameters Table
869
Shunt Resistor Power 1394
D133
100 - 22000 Watts
5.0
300
Shunt Resistor Short Time
Constant 1394
D134
0.25 - 2.55 Seconds
2.2
0.25
Shunt Resistor Value 1394
D132
4- 255 Ohms
3.0
4
Shunt STC Weighting Factor
1394
D136
1 - 100%
3.n
5
SLC I/O Update Rate
D117
0 = Slow
1 = Medium
2 = Fast
1.0
0 (Slow)
SLC Number of Input Bits
D118
0 = 8 (0 - 7)
1 = 24 (0 - 23)
2 = 40 (0 - 39)
1.0
0
SLC Number of Input Floats
D119
+ Integer < 16
2.0
0
SLC Number of MO:
Floats
Integers
D123
D122
+ Integer < 257
+ Integer < 513
3.0
3.0
0
0
SLC Number of MI :
Floats
Integers
D125
D124
+ Integer < 257
+ Integer < 513
3.0
3.0
0
0
SLC Number of Output Bits
D120
0 = 8 (0 - 7)
1 = 24 (0 - 23)
2 = 40 (0 - 39)
1.0
0
SLC Number of Outputs
Floats
D121
+ Integer < 16
2.0
0
Software Overtravel Action
D40
0 = Kill Drive
1 = Stop Motion
2 = Status Only
1.0
1 (Stop Motion)
Status Display Channel*
D37
1 = Serial Port A
2 = Serial Port B
1.0
2 (Serial Port B)
Status Display Refresh Time*
D39
Seconds
3.2
0.5 (Seconds)
Data Parameters
Parameter
Parameter
Number
Units
Value
Format
Default