Publication GMLC-5.2 - November 1999
Motion Controller Functions
629
The Flex_IO_output function is evaluated as 1 (true) if the output is ON
and 0 (false) if it is OFF.
Flex I/O Analog Output
Use the
Flex_IO_analog_output function to directly specify Flex I/O
analog outputs in an expression. This function is available only if you are
running i
CODE
version 3.0 or later (as selected in the Configure Control
Options dialog box).
You define and select Flex I/O analog outputs using the Tag Explorer
(under Flex I/O Analog Output) and Tag Window. It is not necessary to
use this function to specify them directly.
Syntax:
Flex_IO_analog_output[module, address]
The Flex_IO_output function is evaluated as 1 (true) if the output is ON
and 0 (false) if it is OFF.
Argument
Description
Module
The Flex I/O module number (from 0 to 7) from which output is sent.
Address
The address of the selected module’s specific output (from 0 to 15) to be
sent.
Argument
Description
Module
The Flex I/O module number (from 0 to 7) from which output is sent.
Address #
The address of the selected module’s specific output (from 0 to 4) to be
sent.