Locked

An axis is locked whenever either of the following two sets of conditions
are true:

•

Feedback on, electronic gearing off and no position-lock cam or
interpolated motion in progress:

•

No motion (Home, Move, Jog, or Time-Lock Cam) in progress.

•

No axis faults (drive fault, position error, encoder noise or loss,
hardware or software overtravel fault) exists.

•

The output voltage of the axis is not being limited to the servo
output limit parameter (Servo Output Limited).

•

Position error is less than or equal to position lock tolerance.

•

Feedback on, electronic gearing on or position-lock cam or
interpolated motion in progress:

•

No motion (Home, Move, Jog, or Time-Lock Cam) in progress.

•

No axis faults (drive fault, position error, encoder noise or loss,
hardware or software overtravel fault) exits.

•

The output voltage of the axis is not being limited to the servo
output limit parameter (Servo Output Limited).

•

Position error is less that or equal to position lock tolerance.

When you select Locked in:

The:

Wait for Axis mode

Current task pauses until the selected physical axis is
locked onto its command position (Lock_status = 1).

If Axis mode

Program branches to the top (true) node if the selected
physical axis is locked onto its command position
(Lock_status = 1).