Configuring the UDC Module’s Registers

3-3

3.1

Register and Bit Reference Conventions
Used in this Manual

Register numbers are shown using the convention A/B, where A is the drive A register
number and B is the drive B register number. Note that the Interrupt Status Control
registers and the Application registers are the same for both drive A and drive B.

Register descriptions are shown in the following format:

Register Name: Functional name of the register (e.g., Torque Reference Register).

Register Numbers: Memory addresses of registers A and B.

Sug. Var. Name: Suggested variable name for the register (e.g., TRQ_REF%).

Units: Scaling unit applied to the value stored in the register (e.g., counts,

amps

10, etc.).

Range: The upper and lower limits of the value, where applicable (e.g. -4095 to
+4095).

Access: The level of access by the application task (Read, Write, or Read/Write).

Throughout this manual, bit descriptions are shown in the following format:

Bit Name: Functional name of the bit (e.g., DC Bus Over Voltage Fault).

Bit Number: The specific bit location within the register (e.g., Bit 0).

Hex Value: The position within the 16 bit register (e.g., Bit Number 4 = 0010H)

Sug. Var. Name: Suggested variable name for this bit (e.g., FLT_OV@).

Access: The level of access by the application task (e.g., Read/Write).

UDC Error Code: A drive fault’s corresponding error code (e.g. 1018). This is
reported in the log for the task in which the error occurred.

LED: The corresponding status LED, where applicable (e.g., EXT FLT on the PMI
Regulator).

Register Name

Register Numbers

[Functional description]

Sug. Var. Name:
Units:
Range:
Access:

[Additional descriptive details, if required]

Bit Name

Bit Number

[Functional description]

Hex Value:
Sug. Var. Name:
Access:
UDC Error Code:
LED:

[Additional descriptive details, if required]