Configuring the UDC Module’s Registers

3-35

Power Device Status Register (Continued)

204/1204

Phase W-Lower IOC A

Bit 5

The Phase W-Lower A status bit is set if an
IOC or DSAT fault occurs in Power Module
A’s phase W, lower power device.

Hex Value:

0020H

Sug. Var. Name:

W_LOA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Intelligent Power Module A

Bit 6

The Intelligent Power Module A bit is set to
indicate that a DSAT (shoot-through) fault
has occurred in Power Module A. Bits 0 - 5
should be checked to identify the device in
which the fault occurred.

Hex Value:

0040H

Sug. Var. Name:

IPMA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

GDI Fault A

Bit 7

The GDI Fault A bit is set if a problem is
detected with the power supply of Power
Module A’s Gate Driver Interface module.

Hex Value:

0080H

Sug. Var. Name:

GDIA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Charge Fault

Bit 8

The Charge Fault A bit is set if a charge bus
time-out fault occurs in Power Module A.
(refer also to register 202/1202, bit 6).

Hex Value:

0100H

Sug. Var. Name:

CHGA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase U Loss

Bit 9

The Phase U Loss bit is set if AC line phase
U is lost.

Hex Value:

0200H

Sug. Var. Name:

U_PL@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase V Loss

Bit 10

The Phase V Loss bit is set if AC line phase
V is lost.

Hex Value:

0400H

Sug. Var. Name:

V_PL@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A