3-44

SB3000 Drive Configuration and Programming

Parallel Power Module C Status Register (Continued)

221/1221

Phase W-Upper IOC C

Bit 2

The Phase W-Upper C status bit is set if an
IOC or DSAT fault occurs in Power Module
C’s phase W, upper power device.

Hex Value:

0004H

Sug. Var. Name:

W_UPC@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase U-Lower IOC C

Bit 3

The Phase U-Lower IOC CC status bit is set
if an IOC or DSAT fault occurs in Power
Module C’s phase U, lower power device.

Hex Value:

0008H

Sug. Var. Name:

U_LOC@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase V-Lower IOC C

Bit 4

The Phase V-Lower C status bit is set if an
IOC or DSAT fault occurs in Power Module
C’s phase V, lower power device.

Hex Value:

0010H

Sug. Var. Name:

V_LOC@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase W-Lower IOC C

Bit 5

The Phase W-Lower C status bit is set if an
IOC or DSAT fault occurs in Power Module
C’s phase W, lower power device.

Hex Value:

0020H

Sug. Var. Name:

W_LOC@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Intelligent Power Module C

Bit 6

The Intelligent Power Module C bit is set to
indicate that a DSAT (shoot-through) fault
has occurred in Power Module C.

Hex Value:

0040H

Sug. Var. Name:

IPUC@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Bits 0 - 5 of this register should be checked to identify the device in which the fault
occurred.

Advertising