SB3000 Drive Configuration and Programming

Power Device Status Register (Continued)

204/1204

Phase W Loss

Bit 11

The Phase W Loss bit is set if AC line phase
W is lost.

Hex Value:

0400H

Sug. Var. Name:

W_PL@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Over Temperature A

Bit 12

The Over Temperature A bit is set if an over
temperature fault or warning occurs in
Power Module A.

Hex Value:

1000H

Sug. Var. Name:

OTA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase U Current Sharing A

Bit 13

The Phase U Current Sharing A bit is set if
Power Module A is not carrying its share of
the phase U current.

Hex Value:

2000H

Sug. Var. Name:

U_SHRA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase V Current Sharing A

Bit 14

The Phase V Current Sharing A bit is set if
Power Module A is not carrying its share of
the phase V current.

Hex Value:

4000H

Sug. Var. Name:

V_SHRA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase W Current Sharing A

Bit 15

The Phase W Current Sharing A bit is set if
Power Module A is not carrying its share of
the phase W current.

Hex Value:

8000H

Sug. Var. Name:

W_SHRA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A