Rockwell Automation SB3000 Configuration and Programming User Manual
Page 54

3-36
SB3000 Drive Configuration and Programming
Power Device Status Register (Continued)
204/1204
Phase W Loss
Bit 11
The Phase W Loss bit is set if AC line phase
W is lost.
Hex Value:
0400H
Sug. Var. Name:
W_PL@
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Over Temperature A
Bit 12
The Over Temperature A bit is set if an over
temperature fault or warning occurs in
Power Module A.
Hex Value:
1000H
Sug. Var. Name:
OTA@
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Phase U Current Sharing A
Bit 13
The Phase U Current Sharing A bit is set if
Power Module A is not carrying its share of
the phase U current.
Hex Value:
2000H
Sug. Var. Name:
U_SHRA@
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Phase V Current Sharing A
Bit 14
The Phase V Current Sharing A bit is set if
Power Module A is not carrying its share of
the phase V current.
Hex Value:
4000H
Sug. Var. Name:
V_SHRA@
Access:
Read only
UDC Error Code:
N/A
LED:
N/A
Phase W Current Sharing A
Bit 15
The Phase W Current Sharing A bit is set if
Power Module A is not carrying its share of
the phase W current.
Hex Value:
8000H
Sug. Var. Name:
W_SHRA@
Access:
Read only
UDC Error Code:
N/A
LED:
N/A