Rockwell Automation SB3000 Configuration and Programming User Manual

Page 64

Advertising
background image

3-46

SB3000 Drive Configuration and Programming

Power-Up Self-Calibration Faults

,I DQ\ RI WKH SRZHUXS VHOIFDOLEUDWLRQ IDXOWV RFFXUV UHSODFH WKH $& 3RZHU 7HFKQRORJ\

PRGXOH LQ WKH 6% 5HFWLILHU©V 30, UDFN 1RWH WKDW U

egister 202, bit 11

(FLT_PTM@) will also be set.

Run Time AC Power Technology Module Faults

Diagnostic Fault Code Register

222/1222

The Diagnostic Fault Code register displays an error code to help
diagnose the cause of a problem reported in other registers.



Note that this register is available for monitoring only. It cannot be
referenced in an application task.

Sug. Var. Name:

DIAG_FLT%

Units:

N/A

Range:

N/A

Access:

Read only

Code

Fault

1

D/A high voltage error (+10% out of tolerance)

2

D/A low voltage error (-10% out of tolerance)

3

Torque current loop proportional gain not within calibration limits

4

Flux current loop proportional gain not within calibration limits

5

Flux current loop integrator time constant not within calibrated limits

6

Torque current loop integrator time constant not within calibrated limits

7

Harmonic injection error

8

Harmonic DAC limit error

9

Harmonic DAC low error

10

Harmonic DAC range error

11

Programmable current limit fault

12

VAC integrator error

13

A/D converter interrupt error

14

Pulse Width Modulator frequency error

15

DC bus current not zero at power-up.

16

Phase U current not zero at power-up.

17

Phase W current not zero at power-up.

Code

Fault

Description/Action

20

Power supply monitor tripped

Power supply level on the AC Power
Technology module (ACPTM) out of
tolerance.

Replace the ACPTM, PMI rack, and/or
Power Supply.

21

AC power technology
watchdog time-out

ACPTM watchdog timer has expired.

Replace the ACPTM, PMI rack, and/or
Power Supply.