Page 60

Advertising
background image

3-42

SB3000 Drive Configuration and Programming

Parallel Power Module B Status Register (Continued)

220/1220

Phase W-Lower IOC B

Bit 5

The Phase W-Lower B status bit is set if an
IOC or DSAT fault occurs in Power Module
B’s phase W, lower power device.

Hex Value:

0020H

Sug. Var. Name:

W_LOB@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Intelligent Power Module B

Bit 6

The Intelligent Power Module B bit is set to
indicate that a DSAT (shoot-through) fault
has occurred in Power Module B.

Hex Value:

0040H

Sug. Var. Name:

IPUB@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Bits 0 - 5 of this register should be checked to identify the device in which the fault
occurred.

GDI Fault B

Bit 7

The GDI Fault B bit is set if a fault is
detected in the power supply of Power
Module B’s Gate Driver Interface module.

Hex Value:

0080H

Sug. Var. Name:

GDIB@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Charge Fault B

Bit 8

The Charge Fault B bit is set if a charge bus
time-out fault occurs in Power Module B
(refer also to register 202/1202, bit 6).

Hex Value:

0100H

Sug. Var. Name:

CHGB@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Over Temperature B

Bit 12

The Over Temperature B bit is set if an over
temperature fault or warning occurs in
Power Module B.

Hex Value:

1000H

Sug. Var. Name:

OTB@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A