3-34

SB3000 Drive Configuration and Programming

Power Device Status Register

204/1204

The bits in the Power Device Status register indicate the status of the power devices in Power Module A (the
Rectifier’s main power module). When multiple power modules are connected in parallel, status registers
220/1220 and 221/1221 are used for Power Modules B and C, respectively.

If an IOC (overcurrent) fault is detected, the associated phase upper and lower status bits are set. If a phase
DSAT (shoot-through) fault is detected, the associated phase status bits are set and the Intelligent Power
Module bit, IPUA@, is set.

Phase U-Upper IOC A

Bit 0

The Phase U-Upper IOC A status bit is set if
an IOC or DSAT fault occurs in Power
Module A’s phase U, upper power device.

Hex Value:

0001H

Sug. Var. Name:

U_UPA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase V-Upper IOC A

Bit 1

The Phase V-Upper A status bit is set if an
IOC or DSAT fault occurs in Power Module
A’s phase V, upper power device.

Hex Value:

0002H

Sug. Var. Name:

V_UPA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase W-Upper IOC A

Bit 2

The Phase W-Upper A status bit is set if an
IOC or DSAT fault occurs in Power Module
A’s phase W, upper power device.

Hex Value:

0004H

Sug. Var. Name:

W_UPA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase U-Lower IOC A

Bit 3

The Phase U-Lower A status bit is set if an
IOC or DSAT fault occurs in Power Module
A’s phase U, lower power device.

Hex Value:

0008H

Sug. Var. Name:

U_LOA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A

Phase V-Lower IOC A

Bit 4

The Phase V-Lower A status bit is set if an
IOC or DSAT fault occurs in Power Module
A’s phase V, lower power device.

Hex Value:

0010H

Sug. Var. Name:

V_LOA@

Access:

Read only

UDC Error Code:

N/A

LED:

N/A