Show vlan – Dell PowerEdge FX2/FX2s User Manual

Page 160

Advertising
background image

Status

Definition

Length: 93 (+/- 1)
meters, Status:
Open

An opening is detected on the cable. The location, in this
Example is 93 meters. The open is accurate to plus or minus
one meter.

Status:
Impedance
Mismatch

There is an impedance mismatch in the cables.

Example

Dell#show tdr tengigabitethernet 0/1

Time since last test: 00:00:02

Pair A, Length: OK Status: Terminated

Pair B, Length: 92 (+/- 1) meters, Status: Short

Pair C, Length: 93 (+/- 1) meters, Status: Open

Pair D, Length: 0 (+/- 1) meters, Status: Impedance Mismatch

Related
Commands

tdr-cable-test

— Runs the TDR test.

show vlan

Displays the current VLAN configurations on the switch.

Syntax

show vlan [brief |id vlan-id | name vlan-name]

Parameters

brief

(OPTIONAL) Enter the keyword brief to display the
following information:

• VLAN ID
• VLAN name (left blank if none is configured.)
• Spanning Tree Group ID
• MAC address aging time
• IP address

id vlan-id

(OPTIONAL) Enter the keyword id followed by a number
from 1 to 4094. Only information on the VLAN specified is
displayed

name vlan-
name

(OPTIONAL) Enter the keyword name followed by the name
configured for the VLAN. Only information on the VLAN
named is displayed.

Command
Modes

• EXEC
• EXEC Privilege

Command
History

Version 9.4(0.0)

Supported on the FN I/O aggregator.

160