Fcoe-map – Dell PowerEdge FX2/FX2s User Manual
Page 302

• tlv: enables traces for DCBX TLVs.
Defaults
none
Command
Modes
EXEC Privilege
Command
History
Version 9.4(0.0)
Supported on the FN I/O aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.
fcoe-map
Create an FCoE map which contains the parameters used to configure the links between server CNAs
and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port.
Syntax
fcoe-map map-name
Parameters
map-name
Maximum: 32 alphanumeric characters.
Defaults
On the FN2210S Aggregator with PMUX modules, the following parameters are
applied on all the PMUX module interfaces:
• Description: SAN_FABRIC
• Fabric-id: 1002
• Fcoe-vlan: 1002
• Fc-map: 0x0efc00
• Fcf-priority: 128
• Fka-adv-period: 8000mSec
• Keepalive: enable
• Vlan priority: 3
Command
Modes
CONFIGURATION
INTERFACE
Command
History
Version 9.6(0.0)
Supported on the FN2210S Aggregator with the PMUX
module.
Version 9.3(0.0)
Introduced on the M I/O Aggregator with the PMUX module.
Usage
Information
An FCoE map is a template used to map FCoE and FC parameters in a converged
fabric. An FCoE map is used to virtualize upstream FC ports on an FN2210S
Aggregator with the PMUX module NPIV proxy gateway so that they appear to
downstream server CNA ports as FCoE forwarder (FCF) ports on an FCoE network.
When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map
allows the switch to operate as an FCoE-FC bridge between an FC SAN and an
302