9.1 Purpose

The temperature of a fastener effects the overall physical length, as well as the
velocity of a fastener. As the temperature of a fastener increases, the ultrasonic
length increases at a rate greater than the physical change in length. If the user
intends to measure the same fastener at different time intervals over the service
life of the bolt, temperature compensation is very important to produce accurate
results. However, if a fastener will only be measured once, never to be
measured again, temperature compensation is not needed, as long as the
reference length and elongation are measured at the same temperature and
time.

The thermal expansion of the fastener and the ultrasonic change in velocity as a
result of temperature are two separate effects. However, for the purpose of the
MINI-MAX, they are combined in a single factor known as the Temperature
Coefficient (Tc). The sections that follow outline the procedures for selecting and
using the temperature compensation mode with the accessory temperature
sensor.

9.2 Manual Mode

The manual mode option relies on the user to enter in the current temperature
before measuring. This is useful to those users that do not require temperature
compensation, or have an external temperature device measuring the
temperature.

Selecting Manual Temperature Mode

1) Press the

MENU key once to activate the menu items tab. Press the

MENU key multiple times to tab right, and the ESC key multiple times to

tab left, until the

UTIL menu is highlighted and displaying the submenu

items.