Edge Port Conf/Oper

Display the current edge port conf/oper

P2P MAC Conf/Oper

Display the current P2P MAC conf/oper

Port Role

Display the current prot role

Port State

Display the current port state

4.6.6 MST Instance Configuration

This page allows the user to configure MST Instance Configuration. The MST Instance Setting, Information and Status

screens in

Figure 4-6-12

,

Figure 4-6-13

&

Figure 4-6-14

appear.

Figure 4-6-12

MST Instance Setting Page Screenshot

The page includes the following fields:

Object

Description

MSTI ID

Allow assign MSTI ID. The range for the MSTI ID is 1-15.

VLAN List (1-4096)

Allow assign VLAN list for special MSTI ID. The range for the VLAN list is

1-4094.

Priority

Controls the bridge priority. Lower numerical values have better priority. The

bridge priority plus the MSTI instance number, concatenated with the 6-byte

MAC address of the switch forms a Bridge Identifier.

Buttons

: Click to apply changes.