2 reboot switch – Interlogix NS3500-28T-4S User Manual User Manual
Page 354

354
Figure 4-15-1
Factory Default Page Screenshot
After the “Factory” button is pressed and rebooted, the system will load the default IP settings as follows:
。
Default IP address: 192.168.0.100
。
Subnet mask: 255.255.255.0
。
Default Gateway: 192.168.0.254
。
The other setting value is back to disable or none.
To reset the Managed Switch to the Factory default setting, you can also press the hardware reset
button on the front panel for about 10 seconds. After the device is rebooted, uou can login the
management WEB interface within the same subnet of 192.168.0.xx.
4.15.2 Reboot Switch
The Reboot page enables the device to be rebooted from a remote location. Once the Reboot button is pressed, user
has to re-login the WEB interface about 60 seconds later. The Reboot Switch screen in
Figure 4-15-2
appears and
click to reboot the system.
Figure 4-15-2
Reboot Switch Page Screenshot