2 port setting – Interlogix NS3500-28T-4S User Manual User Manual
Page 287

287
The page includes the following fields:
Object
Description
Unit
Controls the unit of measure for the storm control rate as "pps" or "bps". The
default value is "bps".
Preamble & IFG
Set the excluded or included interframe gap
Buttons
: Click to apply changes.
Figure 4-9-70
Storm Control Global Information Page Screenshot
The page includes the following fields:
Object
Description
Unit
Display the current unit.
Preamble & IFG
Display the current preamble & IFG.
4.9.12.2 Port Setting
Storm control for the switch is configured on this page. There are three types of storm rate control:
Broadcast
storm rate control
Unknown Unicast
storm rate control
Unknow Multicast
storm rate contro.l
The configuration indicates the permitted packet rate for unknown unicast, unknown multicast, or broadcast traffic
across the switch. The Storm Control Configuration screens in
Figure 4-9-71
&
Figure 4-9-72
appear.