2 rmon event – Interlogix NS3500-28T-4S User Manual User Manual

Page 344

Advertising
background image

344

CRC/Alignment Errors

The total number of packets received that had a length (excluding framing bits,

but including FCS octets) of between 64 and 1518 octets.

Undersize Packets

The total number of packets received that were less than 64 octets.

Oversize Packets

The total number of packets received that were longer than 1518 octets.

Fragements

The number of frames which size is less than 64 octets received with invalid

CRC.

Jabbbers

The number of frames which size is larger than 64 octets received with invalid

CRC.

Collisions

The best estimate of the total number of collisions on this Ethernet segment.

64 Bytes Frame

The total number of packets (including bad packets) received that were 64

octets in length.

65~127 Byte Frames

The total number of packets (including bad packets) received that were

between 65 to 127 octets in length.

128~255 Byte Frames

The total number of packets (including bad packets) received that were

between 128 to 255 octets in length.

256~511 Byte Frames

The total number of packets (including bad packets) received that were

between 256 to 511 octets in length.

512~1023 Byte Frames

The total number of packets (including bad packets) received that were

between 512 to 1023 octets in length.

1024~1518 Byte

Frames

The total number of packets (including bad packets) received that were

between 1024 to 1518 octets in length.

Buttons

: Click to clear the RMON statistics.

4.14.2 RMON Event

Configure RMON Event table on this Page. The RMON Event screens in

Figure 4-14-2

&

Figure 4-14-3

appear.

Advertising