Chapter 2: Reporting codes

NX-6V2 Control Panel Installation Manual

11

System clock

To set the system clock:

1. Enter *, 9, 7, master code. The Service LED begins flashing.

2. Enter the clock time (military time). Hour: 00 through 23, where 00 is

midnight, 01 is 1:00 a.m., 23 is 11:00 p.m. Minutes: 00 to 59. For example,
3.25 a.m. = 0, 3, 2, 5; and 5:00 p.m. = 1, 7, 0, 0.

User codes

To change the user codes:

1. Enter *, 5, master code. The Ready LED begins flashing.

2. Enter the two-digit user number (for example, 03 for user 3). The maximum

number of users is 40.

3. Enter the new user code designated for that individual. The Ready LED

begins flashing, indicating the code was accepted. If the code was rejected, a
beep sounds three times.

If another user code needs to be programmed, repeat the process.

4. Press # while the Ready LED is flashing to exit the user code programming

mode.

User authority level

To assign user authority levels:

1. Enter *, 6, master code. The Ready LED begins flashing.

2. Enter the two-digit user number. The Ready LED illuminates and the Instant

LED begins flashing.

3. Turn on the LED for the features you want. See Table 5 on page 12 for a

description of each LED.

4. Enter *. The Instant LED will illuminate steady.

5. Now you are in partition enable mode. This tells the system what partition this

user can arm/disarm. LEDs 1 and 2 illuminate for each partition that the user
has authorization for. To change any of these numbers, press 1 or 2 to toggle
the corresponding LED off/on, indicating the user is assigned or not assigned
access to that partition.

6. Enter *. This returns you to step 2, where you can enter another user number

to assign attributes for. You may continue this procedure until you have