Programming locations, Quick start programming, Locations 0 to 18 - reporting – Interlogix NX-6V2 Rev C Installation Manual User Manual

Page 21

Advertising
background image

Chapter 2: Reporting codes

NX-6V2 Control Panel Installation Manual

17

Programming locations

This section describes all the programming options for the control panel.

Quick start programming

For most routine installations, the quick start locations allow you to enable a
majority of the options available with the NX-6V2 (when communicating in
Contact ID or SIA formats). The quick start locations include:

• Location 0 - Phone 1
• Location 1 - Phone 1 account code
• Location 2 - Phone 1 communicator format
• Location 3 - Phone 1 dial attempts/backup control
• Location 6 - Phone 2
• Location 7 - Phone 2 account code
• Location 8 - Phone 2 communicator format
• Location 19 - Download access code
• Location 20 - Number of rings to answer
• Location 21 - Download control
• Location 22 - Download call back number
• Location 23 - Feature report selection/partition feature selection
• Location 24 - Entry/exit times
• Location 25 - Zone type selection for zones 1 to 8
• Location 37 - System reporting, operation, and siren options
• Location 38 - Swinger shutdown count
• Location 39 - Keypad sounder control
• Location 40 - System timers
• Location 42 - Go to program code
• Location 44 - Duress code
• Location 51 - Autotest control

Locations 0 to 18 - Reporting

Location 0 - Phone 1

Location 0 has 20 segments of numerical data. Use this location to program
phone 1. The default for each segment is 14.

• To program a delay of 4 seconds, enter 13 in the appropriate segment.
• To program tone dialing, enter 15 in the segment where tone dialing begins.
• If the entire number is tone dialing, enter 15 in the first segment.
• Enter 11 for a *, and 12 for a #.