Interlogix NX-6V2 Rev C Installation Manual User Manual

Page 71

Advertising
background image

Appendix B: Reporting codes

NX-6V2 Control Panel Installation Manual

67

Loc. Description

Default

Setting

37

Siren and system supervision

Segment 1

1 = Siren sounds for phone line cut while armed

2 = Siren sounds for phone line cut while

disarmed

3 = Siren blasts at arming

4 = Siren blasts at exit delay expiration

5 = Siren blasts at closing kissoff

6 = Siren sounds during a cross-zone verification time

7 = Siren sounds for a tam per

8 = Siren blasts one time for keysw itch, tw o times for

disarming

Segment 2

1 = Convert siren driver to voltage out

2 = Siren sounds for expander trouble

3 = Immediate restore by zone

4 = Dynamic battery test upon arming

5 = Battery missing test every 12 seconds

6 = Manual bell test during *, 4, 4 test function

7 = Manual communicator test during *, 4, 4 test

function

8 = Box tamper enabled

Segment 3

1 = Box tamper report enabled

2 = AC fail report enabled

3 = Low battery report enabled

4 = AUX pow er over current report enabled

5 = Siren supervision report enabled

6 = Telephone line cut report enabled

7 = Ground fault detection report enabled

8 = Expander trouble report enabled

Segment 4

1 = Failure to communicate report enabled

2 = Log full report enabled

3 = Autotest report enabled

4 = Start and end programming report enabled

5 = End dow nload report enabled

6 = Sensor low battery report enabled

7 = Sensor missing report enabled

8 = First to open/last to close enabled

Segment 5

1 = Lost clock service LED enabled

2 = Zone doubling enabled

3 = Disable on-board eight zones

4 = Enable tw o trips on the same cross-zone to

activate the alarm

5 = Disable bypass reports for force armed zones

6 = Reserved

7 = Clock uses internal crystal

8 = Disable temporal siren on fire

Segment 6

1 = Enable tw o-w ire smoke detector

2 = Reserved

3 = Enable zone activity in hours (not days)

4 = Enable Daylight Saving Time (DST)

5 = Reserved

6 = Disable Clean Me report

7 = Disable start/end test report

8 = Enable auto LED extinguish

Segment 7 = Reserved

38

Swinger shutdown count

1

39

Keypad sounder control

Segment 1

1 = Keypad sounds for telephone line cut w hen in the armed state

2 = Keypad sounds for telephone line cut w hen in the disarmed state

3 = Keypad sounds upon AC pow er failure

4 = Keypad sounds upon low battery detection

5 = Keypad sounds during cross zone trip time

6 = Keypad sounds for tamper alarm

7 = Reserved

8 = Keypad sounds for expander trouble

40

System timers

Segment 1 = Dynamic battery test duration (0 to 255)

0 (minutes)

Segment 2 = AC failure report delay (0 to 255

minutes)

5 (minutes)

Segment 3 = Pow er up delay (0 to 60)

60 (seconds)

Advertising