Appendix B: Reporting codes

NX-6V2 Control Panel Installation Manual

65

Loc. Description

Default

Setting

11

Partition reported to phone 2

Segment 1

1 = Partition 1

2 = Partition 2

12

Phone 3 (20 segments)

14 (each segment)

13

Phone 3 account code

10, 10, 10, 10, 10, 10

14

Phone 3 communicator format

0

15

Phone 3 dial attempts
Backup control

8

0

16

Phone 3 events reported

Segment 1

1 = Alarms and restores

2 = Open/close

3 = Bypass

4 = Zone trouble

5 = Pow er trouble

6 = Siren and telephone fault

7 = Test reports

8 = Program, dow nload and log full

Segment 2

1 - Tampers

2 = Short circuit and ground fault

3 = Sensor lost

4 = Sensor low battery

5 = Expander trouble

6 = Failure to communicate

7 = Zone activity monitor

8 = Reserved

17

Partitions reported to phone 3

Segment 1

1 = Partition 1

2 = Partition 2

18

Custom communicator format

Segment 1

1 = ON-1800hz transmit, OFF-1900hz

2 = ON-2300hz handshake, OFF-1400hz

3 = ON-cksum parity, OFF-double round

4 = ON-2-digit code, OFF-1-digit code

5-6 = Reserved

7 = ON-20 pps, OFF-10 or 40 pps

8 = ON-10 pps, OFF-20 or 40 pps

Segment 2

1 = ON-pager format

2 = ON-1400/2300 handshake

3 and 4 = Reserved

5 = ON-Contact ID

6 = ON-SIA

7 = ON-Contact ID or 4+3

8 = ON-DTMF

19

Download access code

8, 4, 8, 0, 0, 0 ,0, 0

20

Number of rings to answer

8

21

Download control

Segment 1

1 = Enable tw o-call answ ering machine defeat

2 = Enable tone sniff answ ering machine defeat

3 = Require callback before dow nloading

4 = Shutdow n control panel

5 = Lock out local programming

6 = Lock out communicator programming

7 = Lock out dow nload section

8 = Enable callback at autotest interval

22

Download callback number (20 segments)

14 (each segment)