NX-6V2 Control Panel Installation Manual

Fail to communicate

The NX-6V2 illuminates the Service LED if a report fails to
reach the central station. If enabled, when the next report is
successfully communicated, a fail to communicate code is
reported. (Location 37)

Fire alarm verification

When enabled, the NX-6V2 verifies a fire alarm by requiring
more than one trip on a smoke detector within a specified time
before creating an alarm (Location 40)

Note: This feature is not approved for residential use in
California.

Force arming

When enabled, the NX-6V2 is force armed with zones violated.
Under this condition, if a force-armable zone is not secure, the
Ready LED flashes. At the end of the exit delay, these zones
become bypassed. If these zones become secured any time
during the arming cycle, they are unbypassed and active in the
system. If bypass report is enabled, the force arming zones
report bypass when they are force armed (default), or to not
report bypass even if bypass report is enabled. (Locations 37
and 110 to 169)

Group bypass

You can program a designated group of zones to bypass by
pressing Bypass, 0, Bypass, Bypass prior to arming (Location
110 to 169)

Immediate restore by zone

If programmed, the NX-6V2 sends alarm and restore reports as
soon as they occur, otherwise the NX-6V2 waits until the siren
time expires. (Location 37)

Keypad activated panics

The NX-6V2 has three keypad activated panics that send
reports to the central station: auxiliary 1 (fire), auxiliary 2
(medical), and keypad panic. Auxiliary 1 activates the temporal
(fire) siren, auxiliary 2 sounds the keypad, and keypad panic is
silent or audible (sound siren). (Location 23)

Keypad sounder control

If programmed, the NX08V2 sounds the keypad sounder for
certain events. (Location 39)

Keypad tamper

If enabled, the NX-6V2 disables the keypad for 60 seconds and
communicates a tamper signal to the central station if 30
keypresses are entered without producing a valid code.
(Location 23)

LED extinguish

This feature extinguishes all LEDs on the keypad, except the
Power LED, after 60 seconds without a keypress. Pressing any
numeric key illuminates all LEDs. (Location 23)

Local programming lockout

This feature disables programming of all locations or specified
location from the keypad (can only be activated via download).
(Location 21)

Log full report

A report is sent to the central station when the event log is full.
(Location 37)

Lost clock service light

If programmed, the NX-6V2 illuminates the Service LED when
the internal clock has an invalid time due to power loss.
(Location 37)