Chapter 2: Reporting codes

NX-6V2 Control Panel Installation Manual

41

Location 56
Restore communicator code

Program the event code for any zone restore for a 4+2
format.

Location 57
Bypass communicator code

Program the event code for a zone bypass for a 4+2
format.

Location 58
Tamper communicator code

Program the event code for a zone tamper for a 4+2
format.

Location 59
Trouble communicator code

Program the trouble communicator code for a 4+2
format.

Location 60
Sensor low battery communicator code

Program the event code zone sensor low battery for a
4+2 format.

Location 61
Sensor missing communicator code

Program the event code for a zone sensor missing for a
4+2 format.

Location 62
Duress communicator code

Program the digits sent for a 2+4 format if the duress
code is enabled (Location 44).

Location 63
Keypad auxiliary 1 communicator code

Program the digits sent for a 4+2 format if the keypad
auxiliary 1 (fire) is enabled (Location 23).

Location 64
Keypad auxiliary 2 communicator code

Program the digits sent for a 4+2 format if the keypad
auxiliary 2 (emergency) is enabled (Location 23).

Location 65
Keypad (police) panic communicator
code

Program the digits sent for a 4+2 format if the keypad
panic is enabled (Location 23).

Location 66
Keypad multiple code entry tamper
communicator code

Program the digits sent for a 4+2 format if the keypad
multiple code entry (tamper) is enabled (Location 23).

Location 67
Box tamper/restore communicator code

Program the digits sent for a 4+2 format if the box
tamper feature is enabled (Location 37).
Segment 1 = box tamper
Segment 2 = box tamper restore.

Location 68
AC fail/restore communicator code

Program the digits sent for a 4+2 format if AC fail
reporting is enabled (Location 37).
Segments 1 and 2 = AC fail
Segments 3 and 4 = AC fail restore

Location 69
Low battery/restore communicator code

Program the digits sent for a 4+2 format if low battery
reporting is enabled (Location 37).
Segments 1 and 2 = low battery reporting
Segments 3 and 4 = low battery restore

Location 70
Aux power overcurrent/restore
communicator code

Program the digits sent for a 4+2 format if aux power
overcurrent reporting is enabled (Location 37).
Segments 1 and 2 = aux power overcurrent reporting
Segments 3 and 4 = aux power overcurrent restore

Location 71
Bell tamper/restore communicator code

Program the digits sent for a 4+2 format if siren
supervision reporting is enabled (Location 37).
Segments 1 and 2 = bell tamper reporting
Segments 3 and 4 = bell tamper restore

Advertising