Chapter 2: Reporting codes

NX-6V2 Control Panel Installation Manual

37

Location 48 - Auxiliary output 2 event and times

Location 48 has two segments of numerical data.

Segment 1 - Use Table 8 below to select the event that activates auxiliary output 2. Default is 1

Segment 2 - Program the timing from 0 to 255 (minutes or seconds, depending on data
programmed in Location 46, segment 1). Programming a 0 makes the output follow the event.
Default is 10 (seconds).

Location 49 - Auxiliary output 3 event and times

Location 49 has two segments of numerical data.

Segment 1 - Use Table 8 below to select the event that activates auxiliary output 3. Default is 2

Segment 2 - Program the timing from 0 to 255 (minutes or seconds, depending on data
programmed in Location 46, segment 1). Programming a 0 makes the output follow the event.
Default is 10 (seconds).

Location 50 - Auxiliary output 4 event and times

Location 50 has two segments of numerical data.

Segment 1 - Use Table 8 below to select the event that activates auxiliary output 4. Default is
21.

Segment 2 - Program the timing from 0 to 255 (minutes or seconds, depending on data
programmed in Location 46, segment 1). Programming a 0 makes the output follow the event.
Default is 10 (seconds).

Table 8 below describes the auxiliary output event selections.

Table 8: Auxiliary output events selection

0 = Burglary alarm

a

1 = Fire alarm (includes keypad panic)

a

2 = 24-hour alarm (includes keypad panics and
zone types 2 and 7)

a

3 = Trouble alarm (does not include phone
trouble)

a

4 = Tamper alarm

a

5 = Yelping siren (burglary)

6 = Temporal siren (fire)

7 = Any siren

8 = Any bypass

9 = AC fail

10 = Low battery (does not include expansion
battery)

11 = Duress

a

12 = Aux 1 keypad zone (keypad fire panic)

a

13 = Aux 2 keypad zone (keypad emergency
panic)

a

14 = Panic keypad zone (keypad police panic)

a

15 = Keypad tamper