Interlogix NX-6V2 Rev C Installation Manual User Manual

Page 22

Advertising
background image

Chapter 2: Reporting codes

18

NX-6V2 Control Panel Installation Manual

Caution:

A call-waiting cancel on a non call-waiting line prevents successful

connection to the central station.

Location 1 Phone 1 account code

Location 1 has six segments of numerical data. Use this location to program the
account code sent when phone 1 is dialed. The default for each segment is 10.
Program a 10 in the segment immediately after the last digit of the account code.
If the account code is six digits long, program all six segments.

Location 2 - Phone 1 communicator format

Location 2 has one segment of numerical data. Use this location to program the
communicator format used to transmit to the receiver connected to phone 1.
Refer to your central station receiver documentation to determine which format is
compatible. Table 6 below describes the formats for this location. If you need a
format other than those listed, review the override options described in Location
18. Program a 15 to create a special format (in addition to the entries in Location
18). The default is 0. If this location contains a 0, the built-in communicator is
disabled and the NX-6V2 functions as a local-only control.

Table 6: Communicator formats

Data Format

Description

0

Local

Communicator is disabled.

1

Universal 4+2

Two-digit event code 1800 Hz transmit 2300 Hz handshake double
round parity 40 pulses per second (pps)

2

3+1 fast (or 4+1)

One-digit event code 1900 Hz transmit 1400 Hz handshake double
round parity 20 pps.

3

Reserved

Reserved

4

Pager

Two-digit event code DTMF transmission.

5

3/1 or 4/1 slow

1800 Hz transmit 2300 Hz handshake double round parity 20 pps hex
capability.

6

3/1 or 4/1 slow

1800 Hz transmit 1400 Hz handshake double round parity 20 pps hex
capability.

7

3/1 or 4/1 fast

1800 Hz transmit 2300 Hz handshake double round parity 40 pps hex
capability.

8

3/1 or 4/1 fast

1800 Hz transmit 1400 Hz handshake double round parity 40 pps hex
capability.

9

3/1 or 4/1 fast with
parity

1800 Hz transmit 2300 Hz handshake single round parity 40 pps hex
capability.

10

3/1 or 4/1 fast with
parity

1800 Hz transmit 1400 Hz handshake single round parity 40 pps hex
capability.

Advertising