Interlogix NX-6V2 Rev C Installation Manual User Manual

Page 23

Advertising
background image

Chapter 2: Reporting codes

NX-6V2 Control Panel Installation Manual

19

Data Format

Description

11

4+2 express

Two-digit event code DTMF transmission.

12

4+2 fast

Two-digit event code 1900 Hz transmit 1400 Hz handshake double
round parity 20 pps.

13

Ademco contact
ID

DTMF (see

“Reporting Ademco Contact ID transmissions” on page

59.

14

SIA

Frequency shift keys (see

“Reporting fixed codes in Contact ID and

SIA

” on page 56).

15

Custom format

See

“Location 18 - Custom communicator format” on page 24.

16

3/1 or 4/1 slow

Same as 5, but sends the alarm event code rather than the zone
number.

17

3/1 or 4/1 slow

Same as 6, but sends the alarm event code rather than the zone
number.

18

3/1 or 4/1 fast

Same as 7, but sends the alarm event code rather than the zone
number.

19

3/1 or 4/1 fast

Same as 8, but send the alarm event code rather than the zone
number.

20

3/1 or 4/1 fast with
parity

Same as 9, but sends the alarm event code rather than the zone
number.

21

3/1 or 4/1 fast with
parity

Same as 10, but sends the alarm event code rather than the zone
number.

22

SIA

SIA with area modifiers.

Location 3 - Phone 1 dial attempts/backup control

Location 3 has two segments of numerical data.

Segment 1 - Phone 1 dial attempts. Program the number of dial attempts (1 to 15) the
communicator makes to phone 1 before ending the notification process. The default is 8, which
means that the communicator makes eight attempts to the first number.

Segment 2 - Phone 1 backup control. Program the backup control for phone 1. The default is 0.

0 = The NX-6V2 will make the designated number of attempts to phone 1 before setting the fail to
communicate condition to stop reporting.

1 = The NX-6V2 will stop trying to communicate after the designated number of attempts have
been made to phone 1.

2 = The NX-6V2 will make the dial attempts in increments of two. The first two attempts are made
to phone 1, the next two attempts to phone 2. This repeats until the total number of attempts
designated in segment 1 is completed.

Advertising