Appendix A: Reporting codes

56

NX-6V2 Control Panel Installation Manual

Reporting fixed codes in Contact ID and SIA

The NX-6V2 can report SIA level 1 transmissions to either or both phone
numbers. Each report consists of an event code and a zone ID (the zone number
that is in alarm) or user ID. Table 12 below shows the event code programmed in
the zone type event code.

Table 12: Reporting fixed codes

Contact ID event

SIA

Description

301

AT

AC fail (device number)

a

301

AR

AC restore (device number)

a

602

RP

Autotest

b

312

YP

Aux power overcurrent (device number)

a

312

YQ

Aux power restore (device number)

a

137

TA

Box tamper (device number)

a

137

TR

Box tamper restore (device number)

a

570

U

c

Bypass restore (zone number)

a

406

OC

Cancel (user number)

a

401

CL

Close (user number)

a

412

RS

Download complete

b

121

HA

Duress

b

451

OK

Early open/late close

b

628

LX

End program

b

605

JL

Event log full

b

457

EE

Exit error (user number)

a

333

ER

Expander restore (device number)

a

333

ET

Expander trouble (device number)

a

454

CI

Fail to close

b

354

RT

Fail to communicate

b

423

DF

Forced door

b

423

DR

Forced door restore

b

310

GF

Ground fault

b

310

GK

Ground fault restore

b

110

FA

Keypad auxiliary 1

b

100

MA

Keypad auxiliary 2

b

120

PA

Keypad panic (audible)

a