Segment 4 - Siren time in minutes, 1 to 254. Default is 8.

Segment 5 - Telephone line cut delay in seconds, 0 to 255 (0 = no monitoring). Default is 0.

Segment 6 - Cross zone time in minutes, 0 to 255 (0 = no cross zoning). Default is 5.

Segment 7 - Chime time in 50 mS increments from 0 to 12 seconds. Default is 3.

Segment 8 - Dial delay in seconds, 15 to 255 (0 = no abort delay). Default is 30.

Segment 9 - Fire alarm verification time in seconds, 120 to 255 (0 = no fire alarm verification).
Default is 0. This feature is not approved for residential use in California.

Segment 10 - Listen-in time in seconds, 0 to 255 (0 = no listen in time). Default is 0.

Segment 11 - Zone activity monitor feature timed in days, 0 to 255 (0 = disabled). Default is 0.

Segment 12 to 14 - Reserved