NX-6V2 Control Panel Installation Manual

79

Manual test

If programmed, the NX-6V2 performs a bell and/or
communicator test when *, 4, 4 is entered while the system is in
the disarmed state. (Location 37)

Night mode

This mode applies to NX-1208E/1248E keypads. In this mode,
the control panel bypasses all zones that have the entry guard
feature enabled. (Locations 23 and 110 tp 169)

Onboard zone disable

For a completely wireless alarm system, the four zones on the
NX-6V2 panel can be disabled. (Location 37)

Program code

The default for the go to program code is 9, 7, 1, 3 when using a
four-digit code. If a six-digit code is used, the default is 9, 7, 1,
3, 0. 0. The program code can be used as an arm/disarm code.
If used as an arm/disarm code, and open/close reports are sent,
the user code is 255. (Location 43)

Quick arm feature

The NX-6V2 has a one-button quick arm feature which is used
to arm the system by pressing the Exit key or the Stay key on
the keypad. User code is 98, if closing reports are sent.
(Location 23)

Recent closing

If enabled, the NX-6V2 sends a recent closing report to the
central station if an alarm occurs within 2 minutes after the
panel is armed. The system always reports user one. (Location
23)

Reexit

The NX-6V2 has the ability to restart the exit delay for a quick
exit without disarming the system by pressing the Exit key while
the system is armed. (Location 23)

Shutdown

When enabled, the keypads turn off all LEDs except the Power
LED and does not accept keypresses (can only be activated via
download). (Location 21)

Siren blast for arming

If programmed, the NX-6V2 gives a 1-second siren blast when
the panel is armed at the end of the exit delay or when the
central station receiver acknowledges the closing report. If also
gives one blast for remote (keyswitch) arming and two blasts for
remote disarming. Four blasts at disarm means that there has
been an alarm. (Location 37)

Siren supervision

The NX-6V2 has a siren supervision circuit that constantly
monitors the siren and reports if the sire are cut. (Location 37)

Silent exit option

The exit delay is silences by pressing *, Exit before arming the
control panel or when using the reexit feature. (Location 37)

Start/end programming and
end downloading

A report is sent when local programming starts and ends. A
report is also sent when a download session ends. (Location
37)